SARI Accredited
SEMA-Aligned Inspectors
Verify on sema.org.uk
SARI No. 0100 — Mr Thelwell
SEMA Trained
Industry-recognised
Same-Day Quotes
Reply within hours
500+ UK Sites
Inspected nationwide

Pallet Racking Inspection Goole

For guidance on racking inspections, legal requirements and racking safety, read the SEMA racking inspection guide.

Racking inspection
Goole

Situated 50 miles inland at the confluence of the River Ouse and River Don directly adjacent to the M62 motorway, Goole is the UK's premier inland maritime port and a major northern powerhouse for passenger rail rolling stock assembly, float glass manufacturing, timber and steel import distribution and agricultural logistics. Massive port sheds, manufacturing halls and public sector archive facilities operate across Goole and District Hospital, Port of Goole (Associated British Ports), Goole 36 Enterprise Zone (Tom Pudding Way), Rawcliffe Road Industrial Estate and Goole Customer Service Centre (East Riding of Yorkshire Council). Heavy freight and container fleets connect directly via M62 Junction 36 (Goole), M62 Junction 37 (Howden), the A614 Rawcliffe Road, the A161 Swinefleet Road and the A63 Howden Bypass. Goole's industrial economy is anchored by inland maritime shipping, steel, timber and bulk cargo manifests at the Port of Goole, alongside rail rolling stock manufacturing, logistics and glass production at Goole 36 Enterprise Zone and agricultural distribution, haulage and Humber corridor warehousing across Rawcliffe Road Industrial Estate. In the public sector, local repositories manage Northern Lincolnshire and Goole NHS Trust community hospital records at Goole and District Hospital as well as unitary council local services, housing and civic documentation. These hubs connect Howden, Selby, Thorne, Doncaster, Scunthorpe,Pontefract, Snaith and Brough. Racking systems across Goole face extreme industrial demands: heavy steel coil, long timber packs, rail car sub-assemblies and float glass stillages at Goole 36, the Port of Goole and Rawcliffe Road test cantilever and high-bay pallet racking to their limits, making annual SEMA racking inspections essential.

All warehouse duty holders, port stevedoring directors, rail and glass manufacturers and public sector facilities managers in Goole must comply with the Provision and Use of Work Equipment Regulations 1998 and the Health and Safety Executive's HSG76 guidance on warehousing and storage. Under PUWER Regulation 5, employers have a strict statutory duty to ensure that all work equipment—including high-bay adjustable pallet racking, heavy-duty timber and steel cantilever racks, drive-in blocks and archive shelving—is maintained in an efficient state, in efficient working order and in good repair. Regulation 6 further mandates that where racking is exposed to operational conditions causing deterioration liable to result in dangerous situations, it must be inspected at suitable intervals by a competent person and after any exceptional event such as a forklift collision, with written records retained. HSG76 establishes a structured three-tier inspection hierarchy to satisfy these legal duties. First, warehouse operatives and MHE drivers must report any rack impact or structural fault immediately. Second, an appointed Person Responsible for Racking Safety must conduct documented weekly or monthly visual checks based on a site-specific risk assessment. Third, an independent SEMA Approved Rack Inspector must perform a thorough annual technical audit. In Goole's heavy port terminals, rail plants at Goole 36 and logistics depots on Rawcliffe Road, failing to uphold PUWER and HSG76 risks HSE enforcement notices, voided insurance and catastrophic rack failure.

When our SEMA Approved Rack Inspectors audit storage systems in Goole, every defect is classified using SEMA's formal Red, Amber and Green risk grading framework to provide clear engineering priorities. During our physical inspection, we measure upright verticality and bracing integrity over a one-metre gauge length against strict SEMA limits: maximum permissible deformations are 3 millimetres down-aisle, 5 millimetres cross-aisle and 10 millimetres of twist, while beam deflection under load must not exceed 1/180th of the clear span. Where severe mechanical impact, sheared baseplate anchors or permanently bowed beams create an immediate threat to structural stability, we issue a Red risk notice; the affected bay must be offloaded immediately and physically cordoned off until repaired with genuine manufacturer components. Where damage exceeds SEMA tolerances without presenting an immediate collapse hazard under current static loads, an Amber risk rating is assigned. Under SEMA protocols, once an Amber bay is unloaded it cannot be reloaded until repaired, and all Amber repairs must be completed within four weeks before automatically escalating to Red status. Minor cosmetic marks within allowable tolerances are recorded as Green risks for monitoring during future audits. Our comprehensive written report includes bay-by-bay defect coordinates, SWL notice verification and floor fixing checks, alongside practical guidance at https://www.rackstor.co.uk/sema-racking-inspection-checklist for your internal safety team.

To book an independent SEMA-approved racking inspection in Goole, Yorkshire and the Humber, call Rack Safety Inspections today on 0800 654 6955.

0800 654 6955

Our Brands

Rack Safety Inspections is part of the Rackstor Group of storage and warehouse specialists.

SEMA Racking Inspection Guide