For guidance on racking inspections, legal requirements and racking safety, read the SEMA racking inspection guide.
Commanding the southern terminus of the M5 motorway where the A30 and A38 trunk routes diverge across the South West peninsula, Exeter is the premier regional distribution, environmental science, academic and county administrative capital of Devon. Major industrial warehousing and institutional archive facilities operate across Royal Devon and Exeter Hospital (Royal Devon University Healthcare NHS Foundation Trust), University of Exeter Streatham Campus, Devon County Council County Hall Topsham Road, Sowton Industrial Estate and Exeter Science Park. National freight trunking and peninsula delivery fleets connect directly via M5 Junction 29, M5 Junction 30, the A30 Honiton Road, the A38 Haldon Hill corridor and the A379 Rydon Lane. Exeter's commercial and institutional economy is powered by regional distribution and high-value equipment parts across Sowton Industrial Estate, alongside Met Office meteorological and climatology data records and advanced research at Exeter Science Park. Across the city, major public and academic repositories manage NHS acute and specialist healthcare filing at Royal Devon and Exeter Hospital, county and city council statutory registry archives at County Hall Topsham Road, and university research papers and historical monographs at the Streatham Campus. These hubs serve surrounding towns including Exmouth, Crediton, Tiverton, Cullompton, Honiton, Dawlish, Teignmouth and Newton Abbot. Racking installations across Exeter face heavy operational demands: regional distribution centres and builders' merchants on Sowton Industrial Estate operate high-bay narrow-aisle adjustable pallet racking and heavy timber or steel cantilever racks under continuous M5 cross-dock shifts, while hospital, council and university vaults carry dense static document loads, making annual SEMA racking inspections essential.
All warehouse duty holders, 3PL distribution directors, science park operators and public sector archive managers in Exeter must comply with the Provision and Use of Work Equipment Regulations 1998 and the Health and Safety Executive's HSG76 guidance on warehousing and storage. Under PUWER Regulation 5, employers have a strict statutory duty to ensure that all work equipment—including adjustable pallet racking, cantilever racking, multi-tier shelving and mobile archive systems—is maintained in an efficient state, in efficient working order and in good repair. Regulation 6 further mandates that where racking is exposed to operational conditions causing deterioration liable to result in dangerous situations, it must be inspected at suitable intervals by a competent person and after any exceptional event such as a forklift collision, with written records retained. HSG76 establishes a structured three-tier inspection hierarchy to satisfy these legal duties. First, warehouse operatives and MHE drivers must report any rack impact or structural fault immediately. Second, an appointed Person Responsible for Racking Safety must conduct documented weekly or monthly visual checks based on a site-specific risk assessment. Third, an independent SEMA Approved Rack Inspector must perform a thorough annual technical audit. In Exeter's high-throughput distribution hubs at Sowton Industrial Estate or critical institutional archives across the city, failing to uphold PUWER and HSG76 risks HSE enforcement notices, voided insurance and catastrophic rack failure.
When our SEMA Approved Rack Inspectors audit storage systems in Exeter, every defect is classified using SEMA's formal Red, Amber and Green risk grading framework to provide clear engineering priorities. During our physical inspection, we measure upright verticality and bracing integrity over a one-metre gauge length against strict SEMA limits: maximum permissible deformations are 3 millimetres down-aisle, 5 millimetres cross-aisle and 10 millimetres of twist, while beam deflection under load must not exceed 1/180th of the clear span. Where severe mechanical impact, sheared baseplate anchors or permanently bowed beams create an immediate threat to structural stability, we issue a Red risk notice; the affected bay must be offloaded immediately and physically cordoned off until repaired with genuine manufacturer components. Where damage exceeds SEMA tolerances without presenting an immediate collapse hazard under current static loads, an Amber risk rating is assigned. Under SEMA protocols, once an Amber bay is unloaded it cannot be reloaded until repaired, and all Amber repairs must be completed within four weeks before automatically escalating to Red status. Minor cosmetic marks within allowable tolerances are recorded as Green risks for monitoring during future audits. Our comprehensive written report includes bay-by-bay defect coordinates, SWL notice verification and floor fixing checks, alongside practical guidance at https://www.rackstor.co.uk/sema-racking-inspection-checklist for your internal safety team.
To book an independent SEMA-approved racking inspection in Exeter, South West, call Rack Safety Inspections today on 0800 654 6955.
Rack Safety Inspections is part of the Rackstor Group of storage and warehouse specialists.