For guidance on racking inspections, legal requirements and racking safety, read the SEMA racking inspection guide.
Wells, the historic cathedral city in Somerset, supports a resilient mix of specialist paper manufacturing, light engineering, professional services and community healthcare across its compact commercial estates. At Keward Mill Trading Estate, Cathedral Park Business Centre and the historic St Cuthbert's Paper Mill Site, manufacturers, builders merchants and business service providers operate adjustable pallet racking, cantilever frames and high-density archive shelving to support light engineering, builders merchants and Mid Somerset warehousing, professional services, consultancy and small business offices, and specialist paper manufacturing heritage and industrial storage. Within the city's civic and wider district healthcare estates, mobile shelving and clinical stores safeguard Somerset NHS Foundation Trust community healthcare and patient files at West Mendip Community Hospital (Glastonbury, serving Wells) and city council civic governance, market licensing and heritage records at Wells Town Hall (Wells City Council). Freight and delivery vehicles serving Wells travel via the A39 Bath Road, the A371 Portway, the A37 Chewton Mendip Road, the B3139 Elm Close and the B3135 Roemead Road. These routes connect Wells directly with surrounding towns including Glastonbury, Street, Shepton Mallet, Cheddar, Radstock and Frome. In builders merchants yards at Keward Mill Trading Estate and paper mill warehouses at St Cuthbert's, storing heavy timber packs, steel sections and dense paper reels places substantial point loads on cantilever arms and pallet beams, while counterbalance forklifts manoeuvring in compact, historic site layouts frequently strike lower upright legs. Annual inspections by a SEMA Approved Racking Inspector ensure structural integrity and compliance across Wells.
For warehouse managers, paper mill directors and public sector estate officers in Wells, compliance with the Provision and Use of Work Equipment Regulations 1998 (PUWER) is a strict legal requirement. Under PUWER Regulation 5, every employer must ensure that storage racking and shelving—whether holding heavy building materials at Keward Mill Trading Estate, specialist paper reels at St Cuthbert's Paper Mill Site, or clinical files at West Mendip Community Hospital—is maintained in an efficient state, in efficient working order and in good repair. Because storage racking is exposed to mechanical handling collisions and heavy static loading that can cause dangerous deterioration, PUWER Regulation 6 mandates periodic inspections at suitable intervals by a competent person, with formal written records retained. The Health and Safety Executive's guidance publication HSG76, Warehousing and Storage: A Guide to Health and Safety, defines the mandatory three-tier inspection hierarchy required to satisfy PUWER. First, warehouse operatives and forklift drivers must report any rack collision or visible structural defect immediately. Second, an appointed Person Responsible for Racking Safety (PRRS) must perform and log regular internal visual checks, normally weekly. Third, an annual expert inspection must be conducted by an independent specialist such as a SEMA Approved Racking Inspector. Failing to uphold this regime in Wells's manufacturing, trade and civic sectors risks HSE enforcement notices, invalidated insurance and prosecution.
Every SEMA racking inspection we conduct in Wells provides duty holders with a comprehensive, engineering-led assessment of their storage systems, classifying each observation under SEMA's traffic-light risk system. Using a one-metre straightedge against impacted upright columns and frame bracing, our SARI-qualified engineer measures whether deflections fall within SEMA's maximum permissible tolerances of 3 millimetres in the down-aisle direction, 5 millimetres in the cross-aisle plane and 10 millimetres on horizontal or diagonal bracing struts. Components within these limits are graded Green, confirming the bay remains safe for full rated loading while being documented for monitoring at the next annual cycle. Where structural distortion exceeds those thresholds, or where essential components such as beam safety locks or floor anchor bolts are missing without creating an immediate collapse hazard, the defect is classified as Amber; under SEMA protocols, Amber bays must be unloaded within four weeks so certified manufacturer replacement parts can be installed, and any Amber defect remaining loaded beyond twenty-eight days automatically escalates to a Red hazard. Severe damage—including deflections exceeding twice the SEMA tolerance, torn steel uprights or damaged beam connectors—is classified as Red, requiring immediate offloading and physical isolation of the bay. Our detailed written report includes bay-by-bay defect locations, load notice audits and compliance guidance referencing https://www.rackstor.co.uk/sema-racking-inspection-checklist.
To book your certified SEMA racking inspection in Wells or anywhere across the South West, call Rack Safety Inspections today on 0800 654 6955.
Rack Safety Inspections is part of the Rackstor Group of storage and warehouse specialists.